Drive slot sensor for storage drive fault was deasserted

ILOM - Oracle Help Center

Each disk drive has an activity LED that indicates an outstanding I/O operation to the drive and a health LED that turns solid amber if a drive fault is detected. Drive faults can be detected in the BIOS POST. SEL messages can contain important information to help you find these problems. Integrated Management Module 2.1 (IMM2.1) error messages ... device is the specific device in the server that caused the event to be generated.. Serviceable Specifies whether user action is required to correct the problem. CIM Information Provides the prefix of the message ID and the sequence number that is used by the CIM message registry. Error event IDs and error codes - IBM - United States

Cisco Bug: CSCua41901 - UCS C220/C240 HDD drive fault critical...

Xbox 360 system will not reade any kind of storage format, like hard drive or flash drive in the usb slot. If you have the Spring 2010 console update installed on your 360 console, you have to configure the USB device it before it is recognized by your Xbox 360 console. vmware esxi - ESX 3i Drive Assertion Fault on otherwise working... ESX 3i Drive Assertion Fault on otherwise working system. Ask Question. up vote 1 down vote favorite. The graphic (below) shows the fault I am seeing in VMWare Infrastructure Client, the drive0 light is also flashing. Cisco Bug: CSCua41901 - UCS C220/C240 HDD drive fault critical... Symptom: HDD Fault Critical SEL events logged in CIMC. description: "HDD1_STATUS: Drive Slot sensor, Drive Fault was asserted" description: "HDD1_STATUS: Drive Slot sensor, Drive Fault was deasserted" Conditions: 1. PERC S300 Degraded, but all drives are fine and running - Dell Ok;Tue Dec 30 10:03:40 2014;Storage Drive 1: Drive Slot sensor for Storage, drive fault was deasserted The spare was in but not part of the pool for the RAID. I added it as a global swap and the RAID added it in during a reboot and the degrade was gone and back to normal.

3 Dec 2015 ... Memory Fault LEDs . ..... Intel® Server Board S2600WT Memory Slot Layout . ..... Hard Drive Activity Header Pin-out ("HDD_LED") . ...... All BMC-owned sensors that show an asserted event status generate a de-assertion SEL ...

HPE Support document - HPE Support Center Rotation is the part of the robotics assembly that turns the robot to face each magazine and the drive. Sled is the part of the robotics assembly that moves the robot towards the OCP or back towards the drive.

Thermal Sensor Input to Fan Speed Control . ..... Intel® Server System P4000CP Storage and Peripheral Drive Bays ............................ 114. 11.1. 2.5” Hard Disk ..... 32. Figure 22. Intel® Server Board S2600CP DIMM Slot Layout . ...... Power supply failure detected – Asserted if power supply module has failed. The following ...

Critical Storage Alert on one of my hosts |VMware Communities That's why you have a drive 7, that's the number matching it's physical slot. If you look at the front of the machine careful, I bet you will see the drive designations, 0,1,2 etc.. That's when you get an error, it will say Drive 3 bad, you know exactly which one to pull or replace. Cisco UCS Manager Troubleshooting Reference Guide ... Each disk drive has an activity LED that indicates an outstanding I/O operation to the drive and a health LED that turns solid amber if a drive fault is detected. Drive faults can be detected in the BIOS POST. SEL messages can contain important information to help you find these problems. Integrated Management Module 2.1 (IMM2.1) error messages ...

Instructions in this User Guide regarding transport, storage, installation and use of the drive must be complied with, including the specified environmental limits.

16 Jan 2017 ... 386 01/07/2017 05:02:01 Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): ... are in a two-disk RAID1, and it had a fault on drive 1 showing sensor=0x03, .... The disks are attached via a storage controller, which is usually either a ... IPMI Management Utilities / Support Requests / #21 Drive info and ... 16 Jan 2017 ... 386 01/07/2017 05:02:01 Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): ... are in a two-disk RAID1, and it had a fault on drive 1 showing sensor=0x03, .... The disks are attached via a storage controller, which is usually either a ... IPMI PET to Platform Message Registry Mapping - DMTF 2 Nov 2009 ... Table 7 – Drive Bay Slot Sensor PET to Platform Message Registry Mapping . ..... to fault. PLAT0537. 01h. Deassert. Drive Fault. Drive. Enabled ..... Initiated Hard. Reset. Power-cycle. Hard. PLAT0274. 05h. Deassert. OS/Run- ...

IPMI PET to Platform Message Registry Mapping - DMTF